Area of application

The excellent flexibility of ceratel® 5910 confirms the chosen design of the hose and makes ceratel® 5910 an easy to mount, very versatile and economic problem solution in process technology.
(Times last updated: February 2013)

Application with ground glass
Air fluidization
Period of application for rubber hose: 14 days / max. 3 weeks
Period of application for ceratel® 5910: in use for over 81 months without failure
Application with quartz sand
Air fluidization
Period of application for rubber hose: 18 - 22 work days
Period of application for ceratel® 5910: in use for 77 months without failure
Application with medium to be fed - sand with varying grain sizes
Air fluidization
Service life of metal arc: approx. 3 – 4 months
ceratel® 5910: delivered in December 2008
(Installation position in March 2012 changed.)
Application with washed, crushed gravel dust
Water fluidization
Period of application for metal arc: 10 – 12 months
Period of application for ceratel® 5910: in use for over 71 months without failure
Application with VA stone chips
Air fluidization
Period of application for rubber sand blasting hoses: 14 days
Period of application for ceratel® 5910: in use since September 2009 without failure